0.6/1KV XLPE Aerial Cable





0.6/1kV XLPE Insulated Aerial Cable
(Aerial Bundled Conductor,  Service Drop Cable)

Description
For single core XLPE insulated or covered aerial cable without messenger or neutral conductor, the phase conductor may be AAC or AAAC or ACSR or Copper.
For more than one core XLPE insulated aerial cable with or without messenger or neutral conductor and with or without street lighting conductor, the phase conductor and street lighting conductor are AAC with XLPE insulation, and the messenger or neutral conductor is AAAC or ACSR with or without XLPE insulation.

Operating Characteristics
Rated voltage: 0.6/1kV
Max. permissible continuous operating temperature of conductor with XLPE insulation: 90°C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250°C
The ambient temperature under installation should not be lower than: -20°C

The bending radius of cable is recommended as following:
When the diameter of cable is less than 25mm: not less than 4 times of the diameter of cable
When the diameter of cable is not less than 25mm: not less than 6 times of the diameter of cable
When the cable is used in alternative current system, the rated voltage of cable should be at least equal to the rated voltage of system; when the cable is used in direct current system, the rated voltage of system should not greater than 1.5 times of the rated voltage of the cable.

Application
XLPE insulated aerial cable as a new-type aerial cable is used for overhead electric power transmission, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.

Manufacturing Standards
GB/T 12527-2008, IEC 60502-1, NF C 33-209, BS 7870-5

Technical Requirements Based on Standard GB/T 14049 and IEC 60502

NF C 33-209 Standard 4 5 6   7 8 9 10
NAME
 
CONDUCTOR
 
Nominal insulation Thickness Cable
 
Type
 
Nominal Cross-section of conductor
 
Core No.
 
Max. resistance Conductor Dia.
 
Tensile strength   Overall Dia.
 
   
(mm 2 )
  20temperature
(Ω /km)
Max.
(mm)
Min.
(mm)
Min.
(daN)
 
(mm)
Min. (mm)   Max.
(mm)
Phase wire/ Non-sling neuter line/ Light cores
 
16
25
35
 
50
70
95
120
150
7
7
7
 
7
12
19
19
19
1.9l
1.20
0.868
 
0.641
0.443
0.320
0.253
0.206
4.6
5.8
6.8
 
7.9
9.7
11.0
12.0
13.9
5.1
6.3
7.3
 
8.4
10.2
12.0
13.1
15.0
190
300
-
 
-
-
-
-
-
1.2
1.4
1.6
 
1.6
1.8
1.8
1.8
1.7
7.0
8.6
10.0
 
11.1
13.3
14.6
15.6
17.3
7.8
9.4
lO. g
 
12.0
14.2
15.7
16.7
18.6
sling neuter line 54.6
70
95
7
7
19
0.63
0.50
0.343
9.2
10.0
12.2
9.6
10.2
12.9
1660
2050
2750
1.6
1.5
1.6
12.3
12.9
15.3**
13.0
13.6
16.3**
Testing wire 1.5 1 12.1 - 1.5 - 1.2 3.7 4.2